PS-BB backboxes are for use with Silent Knight® die-cast metal manual pull stations.
]]>NGA network graphic annunciators are used with Gamewell-FCI® E3 Series® systems. The bright, backlit 1/4-inch video graphics array (VGA) display is supplemented with an intuitive, easy-to-use touchscreen interface that provides up to 512 user-defined messages (up to 77 characters in length) with a selectable font and color for each message. These annunciators indicate events stored in the system event log, the status of analog addressable monitor and control points, and provide diagnostic fault codes/messages. They can be mounted in an enclosure or remotely located.
Features & Benefits:
– 1/4-inch VGA display multipurpose touchscreen provides 512 user-defined messages (up to 77 characters in length) with a selectable font and color for each message
– Software programmable touchscreen interface
– 625K baud ARCNET communications
– User-friendly design
– Includes an RS-232 interface
Certifications:
– UL Standard 864, 9th Edition
– UL Standard UL2572 for Mass Notification
– UL Listed: S1869
– FM Approved 3017416
– MEA FDNY: COA# 6077
– CSFM: 7165-1703-0125
– City of Chicago: Class 1, Class 2, and High Rise
– City of Denver
The Gamewell-FCI, Liquid Crystal Display, Smart Loop Panel (LCD-SLP) is a touchscreen annunciator display used with the S3 Series and E3 Series® Systems. The LCD-SLP provides an easy-to-use, intuitive interface for the operator’s control. The color touchscreen display shows System Status, Event Details, and Service Modes. The five fully-programmable front panel switch/LED combinations provide direct access to perform Device Bypass, Lamp Test and Enable/Disable Groups or Devices. The display features Menu, System Reset, Drift Walk Test, and Five Programmable Switches as physical switches. The LCD-SLP panel’s adaptable design allows it to be mounted in a variety of S3 Series, E3® Series, or Retrofit cabinet installations.
Features & Benefits:
– Provides 4.3” (10.92 cm) color touchscreen display of System Events
– Includes five custom function buttons with LEDs for direct access to system controls
– Shows the Hazard LED to indicate gas, carbon monoxide, or other toxic gases
– Both the E3 Series (ILIMB-E3/ILI95-MB-E3) and the S3 Series (SLP) support up to 15 LCDSLP displays via the RS485 serial interface
– Displays the LED indicators
Certifications:
– UL Listed: S1869
– FM Approved
– MEA FDNY: COA # 6162
– CSFM: 7165-1703:0176
– City of Chicago Approved: Class 1
– Reference Certificate of Compliance: VMA 45894-02C
– ISO 9001 Certification
LCD-E3 keypad displays provide indicating LEDs and operating switches for the main panel display of the E3 Series® expandable emergency evacuation system. Up to six displays may be locally or remotely located from the fire alarm control panel (FACP) via a local RS-485 serial interface.
Features & Benefits:
– 80-character display of system events together with indicating LEDs and control switches
– Backlit LED display with low power consumption
– Switch indicators include alarm acknowledge, system reset/lamp test, signal silence, and trouble acknowledge
– LED indicators include AC power on, alarm, supervisory, system trouble, power fault, and system silence
Certifications:
– UL Listed: S1869; UL 864, 10th Edition
– FM Approved: 3025415
– MEA FDNY: COA# 6077
– CSFM: 7165-1703-0125
– City of Chicago: Class 1, Class 2, and High Rise
– City of Denver
– ISO 9001 Certification
The ANU-48 is a remote annunciator used with the E3 Series® Fire, Mass Notification, Voice Evacuation, and S3 Series Systems. The Gamewell-FCI, ANU-48 LED Driver Module is a remote annunciator that is used in conjunction with the following systems. , E3 Series® Expandable Emergency Evacuation System, E3 Series Combined Fire and Mass Notification System, E3 Series Broadband Voice Evacuation System, S3 Series Small Addressable Fire Alarm Control Panel It provides output for up to eight remote panel switches and 48 remote LEDs, contributing to the versatility and flexibility of the GamewellFCI System. The switches may be programmed to operate as any of the following predefined functions: Speaker Circuit Switch, Fire Fighter Phone Switch, Auxiliary Control Switch using a bank of two switches (use one switch for each On-OffAuto function)
Features & Benefits:
– Includes input for eight software programmable switches, maintained on momentary contact
– Provides output for up to 48 remote LEDs or driver circuits
– The INI-VG Series, ILI-MB-E3/ILI95-MB-E3 or SLP (Smart Loop Panel) can support up to 16 ANU-48 LED driver modules or ASM-16 switch modules for a total of 128 switches and 768 LEDs
– Installed up to 3,000 feet (914.4 m) from the control panel, and up to 15 additional annunciators can be connected
Certifications:
– Listed under UL® Standard 864, 10th Edition
– Listed under UL® Standard UL2572, 2nd
– Edition for Mass Notification
RPT-E3 ARCNET network repeaters are for use with E3 Series® and S3 Series fire alarm control panels (FACPs). They allow remote subassemblies to connect to broadband networks from remote locations. Models available that connect using either unshielded, twisted pair, copper wire, or using 62.5/125 multi-mode fiber-optic cable.
Features & Benefits:
– Provides the capability for networked E3 Series and S3 Series subassemblies to connect in Styles 4 or 7 configurations
– Models available that connect to the network with either unshielded, twisted pair, copper wire, or through single or multi-mode fiber-optic cables
– 625K baud ARCNET repeater
Certifications:
– UL Listed: S1869; 864, 10th Edition
– FM Approved: 3025415
– MEA FDNY: COA# 6077
– CSFM: 7165-1703-0125
– City of Chicago: Class 1, Class 2, and High Rise
– City of Denver
– ISO 9001 Certification
The Gamewell-FCI, MS-7 Series manual fire alarm pull stations are available in a wide variety of configurations. The pull stations comply with the Americans with Disabilities
Act (ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille
text are engraved on the handle. All pull stations include a key lock/reset which is keyed
like with the Gamewell-FCI fire alarm control panels and other manual fire alarm pull stations.
Features & Benefits:
– Addressable stations compatible with all Gamewell-FCI analog addressable fire alarm controls
– Conventional stations suitable for use with any UL® Listed control panel
– Both single and double action stations are available
– Tumbler lock for test and reset keyed alike with Gamewell-FCI controls
– Surface or semi-flush mounting
– Shock and vibration resistant
– Stations (MS-7LOB) Listed for outdoor applications
– Complies with ADA pull force requirements
– *Note: Only the red LED is operative in panels that do not operate in Velocity® mode.
Certifications:
– UL: S2465
– FM: 3023594
– MEA FDNY: 67-02-E Vol. VII
– CSFM:
– 7160-1703:0119
– 7160-1703:0170
– 7160-1703:0109
– ISO 9001 Certification
ThemmO-6SF connects to the signaling line circuits (SLC) of the Gamewell-FCI analog addressable series fire alarm control panels. Each of themmO-6SF supervised control circuits occupies its own address on the system’s SLC that allows each to be fully programmable in its control-by-event sequence of operation. The address of the first supervised output circuit is set with a pair of rotary dials. Each remaining circuit is automatically assigned to its own subsequent address. ThemmO6SF module includes an address disable jumper matrix that allows one, two, or three addresses to be turned off to free these addresses for other purposes. An additional jumper setting selects either Style Y or Style Z circuit configurations. A wide range of configurations is possible including 30V DC, audio input at 25 or 70.7 VRMS, 125V AC, etc. More than one circuit can share a power supply if the current capacity does not exceed the power supply’s output.
Features & Benefits:
– Terminal blocks can accommodate 12 to 18 AWG wire
– Contains external power monitoring
– Provides a flexible jumper configuration feature that allows up to three output circuit addresses to be disabled
– Accommodates multiple external power inputs
– Short circuit protection of external power supplies
– Sources providing AC, DC, or audio inputs
– Designed for use with Gamewell-FCI analog addressable series fire alarm control panels
Certifications:
– CSFM: 7300-1703:0124
– FM: 3023594
– ISO 9001 Certification
– MEA FDNY: 219-02-E Vol. IV
– UL: S1913
Addressable output supervised control modules allow a Gamewell-FCI® analog addressable fire alarm control panel (FACP) to switch an external power supply, such as a DC supply or audio amplifier (up to 80 Vrms), to notify appliances. Addressable output supervised control modules’ notification appliance circuit (NAC) can be wired to either Class A (Style Z) or Class B (Style Y). They also supervise the wiring to the connected loads and report their status to the panel as a normal, open, or short circuit. The modules contain a panel-controlled LED.
Addressable output supervised control modules are designed for installation in the signaling line circuit of any Gamewell-FCI analog addressable FACP. The signaling line circuits of Gamewell-FCI analog addressable FACPs are designed to accommodate up to 159 modules per circuit. Addressable output supervised control modules are designed to mount in a 4-inch (10.16 cm) square junction box.
Features & Benefits:
– Designed as a compact size to allow easy installation
– FM listed as suitable for a releasing device service
– Includes a bi-color LED that flashes green whenever the module is addressed and lights steady red upon activation*
– * Only the red LED is operative in panels that do not operate in Velociti® mode
Certifications:
– UL: S1949
– FM: 3023594
– MEA FDNY: 227-03-E Vol. IV
– CSFM: 7300-1703:0102
– ISO 9001 Certification
– Listed under UL® Standard 864 and UL2572 for Mass Notification
The AOM-2RF Module is designed for installation in the signaling line circuit of any Gamewell-FCI analog addressable fire alarm control panel. The Gamewell-FCI Velociti® Series addressable output relay control module allows a Gamewell-FCI analog addressable fire alarm control panel to switch discrete relay contacts by code command. The relay provides two isolated sets of Form-C contacts that transfer simultaneously. Circuit connections to the relay contacts are not supervised by the module.
Features & Benefits:
– Provides visual rotary, decimal switch addressing (01-159)
– Includes a bi-color LED that flashes green whenever the module is addressed, and lights steady red upon activation
– Designed as a compact size to allow easy installation
Certifications:
– Listed under UL Standard 864
– UL: S1913
– FM: 3023594
– FDNY: COA-219-02-E Vol. VI
– CSFM: 7300-1703:0102
– ISO 9001 Certification