The Gamewell-FCI, Velocity® Series 3 intelligent thermal detectors with integral communication provide a point location for alarm communication and selective maintenance. Designed in a modern bright white color, the Velocity Series 3 is aesthetically pleasing for today’s contemporary buildings.
The Velocity Series 3 heat detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations. The thermal detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency.
Features & Benefits:
– Designed to comply with UL268 7th edition
– Modern profile for improved aesthetics
– Visual rotary, decimal switch addressing (01-159)
– Built-in functional test switch activated by an external magnet
– Dual bicolor LEDs flash green whenever the sensor is addressed, and light steady red on the alarm
– Optional relay, isolator, or sounder bases
– Low standby current
– Analog addressable communication
– Stable communication technique with noise immunity
– Optional remote, single-gang LED Indicator (RA100Z)
– Compatible with Gamewell-FCI analog addressable panels
Certifications:
– UL: S2332
– FM: 3023594
– MEA-FDNY: 219-02-E Vol. VI
– CSFM: 7270-1703-0502
– ISO 9001 Certification
SD365 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber are engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. Exclusively for use with Fire-Lite’s addressable fire alarm control panels (FACPs), the point ID capability allows each detector’s address to be set with rotary, decimal address switches, providing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light provide a local, visible sensor indication.
Features & Benefits:
– Two-wire SLC loop connection
– Stable communication technique with noise immunity
– Built-in tamper-resistant feature- functional test switch activated by external magnet-walk test with address display
– Removable cover and insect-resistant screen for simple field cleaning
– Factory preset at 1.5% nominal sensitivity for panel alarm threshold level
– LED blinks when the unit is polled (communicating with the fire panel) and latches in the alarm
– Low standby current
– Sealed against back pressure
– Designed & to mount directly on the surface or the electrical box
– Separate base with SEMS screws for wiring allows the interchange of photoelectric, ionization, and thermal sensors, optional relay, isolator, and sounder bases
Certifications:
– UL/ULC Listing: S1059
– FM Approved
– CSFM: 7272-0075:0502
Morley-IAS HM Series Thermal Detectors by System Sensor are intelligent point-type thermal sensors that use an accurate thermistor sensing circuit to provide early warning of developing fires, together with addressable communication with the fire alarm panel.
Features & Benefits:
– The detectors have two integral red LEDs that provide a 360° local visual indication of the device status
– Provides fixed 58C temperature sensing
Certifications:
– For HM-FHSE
– EN54-5: 2000 Class A1S
– For HM-FHSE-I
– EN54-17: 2005
Morley-IAS HM Series Thermal Detectors by System Sensor are intelligent point-type thermal sensors that use an accurate thermistor sensing circuit to provide early warning of developing fires, together with addressable communication with the fire alarm panel.
Features & Benefits:
– The detectors have two integral red LEDs that provide a 360° local visual indication of the device status
– Provides fixed 58C temperature sensing
Certifications:
– For HM-FHSE
– EN54-5: 2000 Class A1S
– For HM-FHSE-I
– EN54-17: 2005
designated by UL. The design for these detectors emphasizes economical and highly reliability. A LED will latch on when the detector is in alarm to provide a local alarm signal.
Certifications:
– CE
5600 Series mechanical heat detectors offer property protection against fire and are intended for non-life-safety installations where smoke detectors are inappropriate. The 5600 Series provides a full line of configurations to accommodate a broad range of applications, including both single- and dual-circuit models, available for standard and high-temperature ratings with either fixed-temperature or combination fixed-temperature/rate-of-rise activation. The rate-of-rise elements of the fixed/rate-of-rise models are restorable to accommodate field-testing the units.
To satisfy a variety of installations, the 5600 Series models easily mount to various types of backboxes. The mounting brackets are reversible to allow for flush- and surface-mount back box installations. The 5600 Series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method and the temperature rating in both Fahrenheit and Celsius. The 5600 Series also provides a collector as a post-activation indicator. Once the detectors have been activated, the collectors drop from the affected units to allow easy identification of the specific unit in alarm.
Certifications:
– UL, ULC
– FM
– CSFM
5600 Series mechanical heat detectors offer property protection against fire and are intended for non-life-safety installations where smoke detectors are inappropriate. The 5600 Series provides a full line of configurations to accommodate a broad range of applications, including both single- and dual-circuit models, available for standard and high-temperature ratings with either fixed-temperature or combination fixed-temperature/rate-of-rise activation. The rate-of-rise elements of the fixed/rate-of-rise models are restorable to accommodate field-testing the units.
To satisfy a variety of installations, the 5600 Series models easily mount to various types of backboxes. The mounting brackets are reversible to allow for flush- and surface-mount back box installations. The 5600 Series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method and the temperature rating in both Fahrenheit and Celsius. The 5600 Series also provides a collector as a post-activation indicator. Once the detectors have been activated, the collectors drop from the affected units to allow easy identification of the specific unit in alarm.
Certifications:
– UL, ULC
– FM
– CSFM
5600 Series mechanical heat detectors offer property protection against fire and are intended for non-life-safety installations where smoke detectors are inappropriate. The 5600 Series provides a full line of configurations to accommodate a broad range of applications, including both single- and dual-circuit models, available for standard and high-temperature ratings with either fixed-temperature or combination fixed-temperature/rate-of-rise activation. The rate-of-rise elements of the fixed/rate-of-rise models are restorable to accommodate field-testing the units.
To satisfy a variety of installations, the 5600 Series models easily mount to various types of backboxes. The mounting brackets are reversible to allow for flush- and surface-mount back box installations. The 5600 Series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method and the temperature rating in both Fahrenheit and Celsius. The 5600 Series also provides a collector as a post-activation indicator. Once the detectors have been activated, the collectors drop from the affected units to allow easy identification of the specific unit in alarm.
Certifications:
– UL, ULC
– FM
– CSFM
5600 Series mechanical heat detectors offer property protection against fire and are intended for non-life-safety installations where smoke detectors are inappropriate. The 5600 Series provides a full line of configurations to accommodate a broad range of applications, including both single- and dual-circuit models, available for standard and high-temperature ratings with either fixed-temperature or combination fixed-temperature/rate-of-rise activation. The rate-of-rise elements of the fixed/rate-of-rise models are restorable to accommodate field-testing the units.
To satisfy a variety of installations, the 5600 Series models easily mount to various types of backboxes. The mounting brackets are reversible to allow for flush- and surface-mount back box installations. The 5600 Series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method and the temperature rating in both Fahrenheit and Celsius. The 5600 Series also provides a collector as a post-activation indicator. Once the detectors have been activated, the collectors drop from the affected units to allow easy identification of the specific unit in alarm.
Certifications:
– UL, ULC
– FM
– CSFM
5600 Series mechanical heat detectors offer property protection against fire and are intended for non-life-safety installations where smoke detectors are inappropriate. The 5600 Series provides a full line of configurations to accommodate a broad range of applications, including both single- and dual-circuit models, available for standard and high-temperature ratings with either fixed-temperature or combination fixed-temperature/rate-of-rise activation. The rate-of-rise elements of the fixed/rate-of-rise models are restorable to accommodate field-testing the units.
To satisfy a variety of installations, the 5600 Series models easily mount to various types of backboxes. The mounting brackets are reversible to allow for flush- and surface-mount back box installations. The 5600 Series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method and the temperature rating in both Fahrenheit and Celsius. The 5600 Series also provides a collector as a post-activation indicator. Once the detectors have been activated, the collectors drop from the affected units to allow easy identification of the specific unit in alarm.
Certifications:
– UL, ULC
– FM
– CSFM